The standard package don't include batteries.
At the same time, please forgive us that we are unable to provide the English user manual.
Thanks for your support!
The VICTOR9100C wireless high-voltage transformation ratio tester breaks through the traditional structure and is specially designed and manufactured for online measurement of the primary current, secondary current, transformation ratio, phase and polarity judgment of current transformers and transformers below 35kV in operation. The product consists of a primary current clamp (high-voltage detector), a secondary current clamp, a host, a high-voltage insulation rod, monitoring software, and a communication line. The primary current clamp uses wireless transmission of test data with a transmission distance of 100 meters.
The current clamp is made of high-performance permalloy, with magnetic shielding technology, which is almost unaffected by external magnetic fields, ensuring high precision, high stability, and high reliability for year-round uninterrupted monitoring.
The LCD display of the host is clear at a glance, and it has a large storage space that can store 3000 sets of data.
The high-voltage detector is connected with 5 insulation rods, which can be used for current measurement of lines with insulation sheaths below 60kV or high and low voltage lines with bare conductors below 35kV. The high-voltage current clamp has a unique automatic plug-in structure, which can be convenient by pressing or pulling out the insulation rods. Clamping or evacuating the wire under test saves time and speed. It is widely used in substations, power plants, power inspection departments, industrial and mining enterprises, inspection stations, and electrician maintenance departments for current detection, anti-electricity theft, and field power work. The insulating rod is light and has the characteristics of moisture resistance, high temperature resistance, impact resistance, bending resistance, and high insulation. The insulation class is 110KV.
The monitoring software has online real-time monitoring and historical query functions, dynamic display, maximum, minimum, and average value indication, alarm value setting and alarm indication functions, and historical data reading, consulting, saving, printing and other functions.
VICTOR9100C wireless high voltage ratio tester also has the functions of high and low voltage clamp ammeter, high altitude current tester and other products.
Technical Parameters
Features |
High and low voltage current transformer, transformer primary and secondary circuit current, transformation ratio test, polarity, phase judgment |
power supply |
DC6V alkaline dry battery LR03 (1.5V AAA×4) continuous working for 30 hours |
test method |
Clamp CT |
Primary current Test accuracy |
Range: 0.0A~800A; Resolution: 0.1A; Accuracy: ±0.5%FS |
Secondary current Test accuracy |
Range: 0.00mA~5A; Resolution: 0.01mA; Accuracy: ±0.5%FS |
Variable ratio measurement range |
1~500 |
Variable ratio resolution |
0.1 |
Primary current clamp size |
Jaw size: φ48mm; overall size: 76mm×255mm×31mm; |
Secondary current clamp size |
Jaw size: φ8mm; overall size: 137mm×40mm×19.5mm |
Shift |
Fully automatic gear shift |
Sampling rate |
3 times/sec |
data storage |
3000 groups, press the left arrow key to keep the data and automatically number and store (the data will not be lost if the power is off or the battery is replaced) |
Data retention |
Press the left arrow key to hold the data, the HOLD symbol is displayed, and then press the HOLD key to cancel the hold |
Data access |
Press the right arrow key to enter the data review mode |
Overflow display |
Over-range overflow function: "OL" symbol display |
No signal indication |
When the host does not receive the transmit signal, it prompts "no signal" |
Automatic shut-down |
Approximately 15 minutes after power on, the meter will automatically shut down |
battery voltage |
When the battery voltage is lower than 4.8V, "" is displayed, reminding to replace the battery |
Primary current clamp Transmission distance |
Wireless transmission distance 100M |
Secondary current clamp Length of connection line |
2M |
Display mode |
LCD: 128dots×64dots; backlight function, suitable for dim places |
LCD size |
Display area: 44mm×27mm |
Host size |
78mm×165mm×42mm |
Instrument quality |
5kg (including tool kit and insulating rod) |
Outside interference |
Avoid strong electromagnetic field; avoid 433MHz, 315MHz co-frequency interference |
Working temperature and humidity |
-15℃~50℃; below 70%Rh |
Storage temperature and humidity |
-10℃~60℃; below 70%Rh |
Insulating rod size |
φ32mm, 1m/section, 5 sections |
Insulating rod withstand voltage |
110KV |
Dielectric strength |
Host and detector: AC1000V/rms (between shell and screw) |