|
Features:
1) Dual Independently Controlled Channels2) Wide Signal Bandwidth: 150MHz3) Super High Sampling Rate: 1GSamples/s4) Deep Storage Memory: 8MSamples5) Vertical Range: 2mV/div ~ 10V/div6) Vertical Resolution: 8bit7) Built-in 25MHz Arbitrary Function Generator ( On DSO2D10 & DSO2D15 Only)8) Trigger Type: Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, & IIC9) BUS Decoding and Protocol Analysis Functions: RS232/UART, I2C, SPI, CAN, LIN, etc.10) Versatile Data Saving Functions in Multiple Formats: Settings, Signal and Reference Waveforms, CSV File for Data Values, Waveform Snap Shots, etc.11) Build-in Dual Channel 3-Digit Voltage Meters and One 6-Digit Frequency Counter12) Automatic Measurements for 32 Types of Real-Time Statistic Parameters: Maximum, Minimum, Standard Deviation, etc.13) Can Set Trigger Threshold and Measure Major Parameters Automatically14) Remotely Controllable Through SCPI (Standard Commands for Programable Instruments)15) USB Host/Device for Transferring Data and Connecting to a USB Equipment.
Model Selection Guide
Model
Channel
Bandwidth
Sample Rate
Memory Depth
AFG
(Arbitrary Function Generator)
DS02C10
2Ch
100MHz
1GSa/s
8MSamples
N/A
DS02C15
2Ch
150MHz
1GSa/s
8MSamples
N/A
DS02D10
2Ch + 1Ch
100MHz
1GSa/s
8MSamples
1Ch
DS02D15
2Ch + 1Ch
150MHz
1GSa/s
8MSamples
1Ch
Specification
Model
DSO2D15
DSO2D10
DSO2D15
DSO2C10
Bandwidth
150MHz
100MHz
150MHz
100MHz
Oscilloscope Channels
2Ch
2Ch
2Ch
2Ch
Arbitrary Function Generator
1Ch
1Ch
Horizontal
SEC/DIV Range
2ns/div to 100s/div, in a 1, 2, 5 sequence
Delta Time Measurement Accuracy
(Full Bandwidth)
Single, sampling mode
± (1 sample interval + 100ppm × reading + 0.6ns)
>16 times above average
± (1 sample interval + 100ppm × reading + 0.4ns)
Sample interval = s/div ÷ 200
Vertical
A/D Converter
8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range
2mV/div to 10V/div at input BNC
Offset Range
2mV/div ~ 200mV/div, ±1V
500mV/div ~ 10V/div, ±50V
Selectable Analog Bandwidth Limit (Typical)
20MHz
Low Frequency Response (−3db)
≤10Hz at BNC
Rising Time at BNC (Typical)
DSO2C10
DSO2C15
DSO2D10
DSO2D15
≤3.5ns
≤2.4ns
≤3.5ns
≤2.4ns
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
Vertical Offset Accuracy
±0.1div±2mV±1% Offset
Mathematical Operation
+, −, ×, /, FFT
FFT
Window Function Types: Rectangle, Hanning, Hamming, Blackman, Bartlett and Flat Top
Voltage Measurement Repeatability, Average Acquisition Mode
Under the same setting and environment, ≥16 waveforms are sampled, ΔV of any two averages:
± (3% × value + 0.05 div)
Note: Bandwidth reduced to 6MHz when using a 1X probe
Acquisition
Sample Rate Range
1GSa/s (single channel), 500MSa/s (dual channels)
Acquisition Modes
Normal, Peak, Average & High Resolution
Waveform Interpolation
(sin x)/x
Acquisition Rate (Typical)
Up to 2000 waveform per second per channel (Normal acquisition mode, no measurement)
Minimum Detection Pulse Width
2ns
Single Sequence
Acquisition Mode
Acquisition Stop Time
Normal, Peak Detect
Upon single acquisition on all channels simultaneously
Average
After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128
Memory Depth
Maximum 8M for single channel (4K, 40K, 400K, 4M, 8M optional)
Maximum 4M for dual channels (4K, 40K, 400K, 4M optional)
Trigger
Trigger Type
Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Delay, UART, LIN, CAN, SPI, lIC
Trigger Level Range
±5 divisions from the center of the screen
Mode
Auto, Normal, Single
Level
CH1 ~ CH2
±5 divisions from the center of screen
EXT
0~3.3V [CMOS]
Holdoff Range
20ns ~ 10s
Trigger Level Accuracy
CH1~CH2
0.2 div × volts/div within ±4 divisions from the center of the screen
EXT
± (Set value × 6% + 40mV)
Trigger Sensitivity
±0.2div
Edge Trigger
Slope
Rising, Falling, Rising & Faling
Source
CH1 ~ CH2, Line, External
Pulse Trigger
Polarity
Positive, Negative