Led Display Screen 125L Lab Incubator Constant Temperature Electrothermal Incubator
|
|||||||||||||||
Operation and usage ●Turn on the power and turn on the power switch and the heating switch. ●Press the setting key to enter the temperature set state. The lower row shows the temperature setting value, which can be changed to the desired setting value by shifting, increasing or decreasing the key; then click the“Set” key. ●If the alarm is over-temperature due to the change of the temperature setting value, it can be silenced by pressing any key. ●“◀”Click on this key in the set state to make the set value shift flicker changes. ●“▼”Click this key in the set state, the set value can be decremented, long press this key can make the set value successive decrements. In a timed state, pressing the key for 3 seconds can stop the program. ●“▲”Click this key in the set state, the set value can be incremented, long-press this key to set the value of successive increments. ●If no key is pressed within 1 minute, the controller will return to the normal display state automatically. ●If the upper row of the display window of the controller shows”--”, which means that the temperature sensor or the controller itself is out of order, please carefully check the temperature sensor and its wiring. |
|||||||||||||||
![]() |
01
Ventilation holes
Ventilation holes ensure the circulation of air inside the box, helping to expel any possible waste gases and moisture, and maintain a good environment. |
||||||||||||||
![]() |
02
Led display screen, cleaning intuitive, at a glance |
||||||||||||||
![]() |
03
Stainless steel liner, accurate temperature control. |
||||||||||||||
![]() |
04
High-temperature handle
It can not only withstand the high temperature inside the incubator, but also provide a comfortable grip without deformation or damage due to heat.
|
||||||||||||||
![]() |
05
With a visual window
It is convenient to observe the sample state without opening the door, the field of vision is clear, and the insulation is doubled. |
||||||||||||||
![]() |
06 Includes 2 grid trays | ||||||||||||||
![]() |
07 Thicken the sealing strip to fit the seam perfectly. It has a double stainless steel grid. |
||||||||||||||
Precautions | |||||||||||||||
●Safe operation:
When in use, do not touch the two terminals on the top of the box and
the electrical components on the side or top of the with your hands.
Avoid wiping with a damp cloth or rinsing the equipment with water1. ●Power management: Before use, install the power socket according to regulations, and the upper inclined foot is effectively grounded. The power cord should not be wound around metal objects or placed in damp, high-temperature places to prevent rubber aging and electric leakage. When not in use for a long time, the power supply should be cut off12. ●Sample management: It is forbidden to put corrosive andammable items. When placing precious strains and cultures, it is necessary to observe frequently and immediately cut off the power supply in case of abnormal conditions12. ●Main: Regularly clean and maintain the electric heating constant temperature incubator to keep the equipment running normally. Do not open the temperature controller unless necessary to avoid damage12. High temperature protection: ●When the electric heating constant temperature incubator is used at a higher temperature, be careful not to burn |
|||||||||||||||
You can make order
with no worry. |
On Jun 30, 2025 at 02:01:16 PDT, seller added the following information: