Electrothermal Incubator 110V 125L Laboratory Drying Heat Treatment Equipment

$1350.0
Brand
TECHTONGDA
Model
500BS
MPN
239961
UPC
198462542708
condition
New
110V Electrothermal Incubator 125L Laboratory Drying Baking Wax Melting Heat Treatment Equipment 400W 500BS Led Display Screen Stainless Steel Liner
https://topseller365.com/data/prd/239/961/5.jpg

It is suitable for drying, baking, wax melting and heat treatment in laboratories of industrial and mining enterprises and scientific research institutes.

Parameters:

Models: 500BS
Voltage: 110V
Power: 400W
Working environment temperature: 41°F-104°F(5-40℃)
Temperature fluctuation: +/-32.9°F(+/-0.5℃)
Temperature Control Range: RT+41°F--149°F(RT+5℃--65℃)
Capacity: 125L

https://topseller365.com/data/prd/239/961/15.jpg

Feature:

1.The working room is made of stainless steel or high quality steel plate, which is processed and treated with anticorrosion. The shelf height is adjustable, and the four corners form a semicircle, which is convenient for cleaning.
2.“Double-layer liner” design, safe and reliable, beautiful appearance, easy to open, small space, is the factory workshop processing and manufacturing, office experiment ideal choice.
3.All-round three-dimensional forced air supply technology to ensure the temperature uniformity in the studio.
4.Double-layer tempered glass observation window, adjustable height of test shelf in the work room, clear observation, easy to use.
5.Microcomputer intelligent digital display temperature control instrument accurate temperature control, ensure that the temperature without overshoot, with timing, over-temperature alarm and other functions.
6.Good thermal insulation design, can long-term high-temperature operation, long service life, easy to replace, the greatest degree to achieve green, energy-saving, environmental protection.
7.High-temperature silicone sealing strip, with lock-type loose and tight regulation of the door lock to ensure good sealing, to prevent heat loss.
8.Unique geometric cavity clean design to ensure the perfect active protection of samples.

Details:

https://topseller365.com/data/prd/239/961/19.jpg

https://topseller365.com/data/prd/239/961/20.jpg

https://topseller365.com/data/prd/239/960/18.jpg

https://topseller365.com/data/prd/239/960/7.jpg

Ventilation holes
Ventilation holes ensure the circulation of air inside the box, helping to expel any possible waste gases and moisture, and maintain a good environment.

Led display screen, cleaning intuitive, at a glance

Stainless steel liner, accurate temperature control.

High-temperature handle
It can not only withstand the high temperature inside the incubator, but also provide a comfortable grip without deformation or damage due to heat.

https://topseller365.com/data/prd/239/961/5.jpg

https://topseller365.com/data/prd/239/961/16.jpg

https://topseller365.com/data/prd/239/961/23.jpg

https://topseller365.com/data/prd/239/961/11.jpg

With a visual window
It is convenient to observe the sample state without opening the door, the field of vision is clear, and the insulation is doubled.

Includes 2 grid trays

Thicken the sealing strip to fit the seam perfectly. It has a double stainless steel grid.

 

Operation and usage:

1.Turn on the power and turn on the power switch and the heating switch.
2.Press the setting key to enter the temperature set state. The lower row shows the temperature setting value, which can be changed to the desired setting value by shifting, increasing or decreasing the key; then click the“Set” key.
3.If the alarm is over-temperature due to the change of the temperature setting value, it can be silenced by pressing any key.
4.“◀”Click on this key in the set state to make the set value shift flicker changes.
5.“▼”Click this key in the set state, the set value can be decremented, long press this key can make the set value successive decrements. In a timed state, pressing the key for 3 seconds can stop the program.
6.“▲”Click this key in the set state, the set value can be incremented, long-press this key to set the value of successive increments.
7.If no key is pressed within 1 minute, the controller will return to the normal display state automatically.
8.If the upper row of the display window of the controller shows”--”, which means that the temperature sensor or the controller itself is out of order, please carefully check the temperature sensor and its wiring.

Precautions:

1.Safe operation: When in use, do not touch the two terminals on the top of the box and the electrical components on the side or top of the with your hands. Avoid wiping with a damp cloth or rinsing the equipment with water.
2.Power management: Before use, install the power socket according to regulations, and the upper inclined foot is effectively grounded. The power cord should not be wound around metal objects or placed in damp, high-temperature places to prevent rubber aging and electric leakage. When not in use for a long time, the power supply should be cut off‌.
3.Sample management: It is forbidden to put any corrosive and flammable items. When placing precious strains and cultures, it is necessary to observe frequently and immediately cut off the power supply in case of abnormal conditions‌.
4.Main: Regularly clean and maintain the electric heating constant temperature incubator to keep the equipment running normally. Do not open the temperature controller unless necessary to avoid damage‌.
5.High temperature protection: When the electric heating constant temperature incubator is used at a higher temperature, be careful not to burn‌.the seam perfectly. It has a double stainless steel grid.

Item Number:

Electrothermal incubator (239961)

Shipping & Handling Details

Default  Shipping Cost or Free Shipping Information: 

 Default  shipping cost or free shipping service is only for the customers  from Canada or the lower 48 United States by Canada Post, USPS or the UPS Ground. Customers from other areas or needs other shipping  ways, please contact us.
 Buyers  from Guam, Puerto Rico, Virgin Islands, American Samoa, Alaska,  Hawaii, PO Boxes, APO/FPO addresses or other countries/areas, there will be extra shipping costs, please contact us for more detailed  information.
▲ 
Please  make sure your address is valid for both UPS and USPS services. Any  costs incurred because of incorrect or undeliverable address should  be undertaken by buyer.

Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders  are processed from Monday-Friday; Not on the weekends & public  holidays.

Sales tax / Customs  duties: Any  sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer.

Damage In Shipping: Email or call us First! We will work with you to get the case resolved in  the fastest method.

Return /  Refund

If you are not 100% happy with your purchase, please  contact Us. Please don't directly opened a request or case without  informing us, or else, we will do some discounts on the warranty and  other sales-services later on. Hope for your understanding.

Returns & Exchanges

 All returns must be made within 14 days of delivery date. Items must be  in new, unused condition, with all original materials included with  the shipment. A partial refund may be applied for opened or damaged  items, depending on the condition.
▲ Items  returned under the buyer’s remorse: The return shipping fee must be  covered by the buyer; The original shipping cost will also be  deducted from the refund. 15% restocking fee of the items purchase  price will be charged. 
 Returns  that are the result of our seller's error: Buyer will receive a full  refund of the item as well as shipping charges
▲ 
All returns require a RA (Return Authorization) number that will be given by our seller. Please contact with us at first for more  details.

Defective & Damaged Products 

▲ If product was received damaged or not as described, please send us  some pictures or videos, so we could well understand your problem,  then solve them for you ASAP. Besides, it's much helpful for us to  claim with UPS, remind our related department to pay much more  attention to packaging later on. Hope for your understanding.
 Replacement  or refund of defective or damaged products can only be returned in  exchange for the exact same product, or else, the purchase price  will be refunded back to your original payment method. 
▲ If  an item is received damaged, customer service must be contacted  within 7 days of receiving your item. All returns require a RA  (Return Authorization) number as above.

Warranty & Feedback

 6 months' warranty for the machines, not for the consumables. We stand  behind our products all the item, so even if your warranty period  has expired, you can still seek for service or technical support  from us with low cost.
▲ Any  warranty shipping cost to us is responsible by buyer.
 Any  shipping cost to buyer is responsible by the seller. 
▲ 
We  committee to the customer satisfaction and want to bring you the  best purchase experience. If there is any problems, please contact  us ASAP. If not, please leave us a positive feedback as it's very  important for us. Thanks very much.