tube filament and metal target in the internal X-ray source assembly, a large number of electrons are
generated on the cathode filament of the X-ray tube and move at a high speed in the vacuum tube,
impact the metal target to generate the X-ray. The X-ray penetrate the different tissue densities of the body, such as teeth and muscles after pass through the X-ray window and beam tube, the X-ray which
carry image information through body tissue, are passed through image receiving devices such as
phosphor sheets, film or digital image receivers, to show different densities of human tissue images.
Application Range: used for the teeth to taking an X-ray photography, with an intraoral image
receiver, images are obtained for the clinical diagnosis.
Structural composition: the product consists of the host (including the X-ray tube, controller and
rechargeable battery), beam limiting tube, power adapter, stand and exposure switch.
(1) Safety category:Class Ⅱ or internal power supply class ,does not work while charging.
(2) Classified by electric shock protection type:Type B application section.
(3) Classified by the degree of protection against fluid intake:Common equipment.
(4) Classified by the manufacturer's recommended disinfection and sterilization methods:As required by the manufacturer to carry out.
(5) Classified by the degree of safety for use with flammable anesthetic gases mixed with air or with oxygen or nitrous oxide:NonAP/APG type.
(6) Classified by operation mode:Discontinuous operation,Maximum excitation (open) time: Minimum excitation (close) time =1:30.
(7) The product has no application part with protection against defibrillation discharge effect.
(8) Whether the equipment has a signal output or input part:No.
(9) The product is a common equipment.
(10) Permanent or non-permanent installation equipment:Non-permanent installation equipment.
(11) Radiation type:Ionizing radiation.
(12) Radiation property:X ray.
(13) Radiation distribution:The X-ray radiates from the positive direction of 6cm circle in the window of the limited beam barrel when used.
❖FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Company name: Dreamland Technology Ltd
City, State: Beijing, China
Telephone number: 0371-56645662
FDA for Curing Light: 510(K) Number: K192233, Regulation Number: 21 CFR 872.6070, Product Code: EBZ
FDA for Handpiece: 510(K) Number: K181691, Regulation Number: 872.4200, Classification Product Code: EFB, Subsequent Product Code: EGS
FDA for Scaler: 510(K) Number: K163414, Regulation Number: 872.4850, Product Code: ELC