Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro & 201GAS Burners. Now With LCD Screen!
***Important Note***
When Installing On A Covered Burner You Must Also Purchase The 33902FS Low Profile Junction Box. It Is NOT Included With This Control.
Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 602002FR-363S
Features:
On-Board LCD Screen
Easy to Understand Icons for Inputs and Outputs
Displays micro-amp Flame reading
Display operational information
• Fault History records last 50 fault
cycles to aid the technician in
troubleshooting
• Field Settable Timings
• Pre-purge (0, 10, 30, 90)
• Trial for Ignition Time (4, 6)
• Post-Purge (0, 10, 15, 30, 60, 120)
• Number of Recycles allowed (0, 1, 3)
• Serviceman Reset Protection (3)
• Low Voltage Terminals
TT (can be programmed as Used or Not used)
Blocked Vent input (contact closure, functions as a low voltage limit)
CO input (contact closure) required to start C.F.H ., lockout if not detected during run
Alarm output (dry contacts) 24VAC/DC
Power input (red/white wire) 120 VAC, 60 HZ, 9 VA
Limit circuit input (black wire) 120 VAC, 60 HZ
Motor load (orange wire) 10 FLA / 60 LRA
(reduce by valve and ignition load)
Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA
Valve load (violet wire) 2 amps
Aux 120 VAC, 1 amp
Alarm contacts (dry contacts) 24V, AC/DC, 2A
Operating temperature limits +32°F to +140°F
Storage temperature limits -40°F to +185°F
Thermostat 24 VAC, 0.1A
Blocked Vent 12 VDC. 2mA
CO 12 VDC. 2mA
Agencies UL recognized (US & Canada)
Features:
On-Board LCD Screen
Easy to Understand Icons for Inputs and Outputs
Displays micro-amp Flame reading
Display operational information
• Fault History records last 50 fault
cycles to aid the technician in
troubleshooting
• Field Settable Timings
• Pre-purge (0, 10, 30, 90)
• Trial for Ignition Time (4, 6)
• Post-Purge (0, 10, 15, 30, 60, 120)
• Number of Recycles allowed (0, 1, 3)
• Serviceman Reset Protection (3)
• Low Voltage Terminals
TT (can be programmed as Used or Not used)
Blocked Vent input (contact closure, functions as a low voltage limit)
CO input (contact closure) required to start C.F.H ., lockout if not detected during run
Alarm output (dry contacts) 24VAC/DC
Power input (red/white wire) 120 VAC, 60 HZ, 9 VA
Limit circuit input (black wire) 120 VAC, 60 HZ
Motor load (orange wire) 10 FLA / 60 LRA
(reduce by valve and ignition load)
Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA
Valve load (violet wire) 2 amps
Aux 120 VAC, 1 amp
Alarm contacts (dry contacts) 24V, AC/DC, 2A
Operating temperature limits +32°F to +140°F
Storage temperature limits -40°F to +185°F
Thermostat 24 VAC, 0.1A
Blocked Vent 12 VDC. 2mA
CO 12 VDC. 2mA
Agencies UL recognized (US & Canada)