Voltage type for actuating | AC |
---|
Rated control supply voltage at AC 50 Hz | 110 V |
---|
Rated control supply voltage at AC 60 Hz | 120 V |
---|
Current (Ie), max | 97 A |
---|
Switching frequency, max | 200 ops/h |
---|
Main current circuit resistance | 2 mohm |
---|
Cross section per UL/CSA | 16 |
---|
Rated operational current for contactor at elevator duty (UL/CSA) | 21.0A @ 460V |
---|
Rated operational power for contactor at elevator duty (UL/CSA) | 5Hp @ 230V |
---|
Rated isolation voltage (Ui) | 690V @ IEC |
---|
Rated voltage (Ue) | 690V @ AC, 50/60 Hz |
---|
Rated operational power for contactor at wye-delta | 7.5Hp @ 200V, 60 Hz |
---|
Rated filament current | 22A @ 230/240V, AC-5b |
---|
Power dissipation | 3.2 W @ 400V, AC-3, Ie |
---|
Coil terminal conductor cross section | 1…4 mm² @ 2 conductor |
---|
Rated current (enclosed) | 24A @ 115V, 1-phase per UL/CSA |
---|
Rated power (enclosed) | 7.5Hp @ 230V, 3-phase per UL/CSA |
---|
Coil consumption pick-up (avg/peak) | 14/22 W @ DC (electronic-EA) |
---|
General purpose current (enclosed) | 30 A per UL/CSA |
---|
Capacitance, max | 500 µF @ short-circuit current of 20 kA |
---|
Switching of low inductive loads | 32A @ 440V, AC-7a per IEC 61095 (50 Hz) |
---|
Operating limits, pick-up | (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
---|
Switching of motor load | 23A @ 230V, AC-7b per IEC 61095 (50 Hz) |
---|
Short time withstand (Icw) | 215A @ 10s, 60 °C |
---|
Coil consumption, hold-in | 3 W @ DC (electronic-EA) |
---|
Coil consumption, pick-up | 105VA @ 50 Hz, 60 Hz, 50/60 Hz |
---|
Operating time | 15…30 ms @ AC closing delay |
---|
Total power dissipation | DC control (electronic): 4.9 W @ 400V, AC-3, Ie |
---|
Operating limits, dropout | (0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
---|
Switching of lamps | Gas discharge lA, open: 29A @ 40°C (104 °F), AC-5a |
---|
Switching of hermetically sealed cooling compressor motors | 32A @ 500V, AC-8a (manual reset of overload release (50 Hz)) |
---|
Coil insulation class | Class F per IEC 60085, UL Class 105 |
---|
Rating for switching AC motors | 3-poles: 7.5 kW @ 230V (AC-2, AC-3, AC-4), 3-phase (50 Hz) |
---|
BS88 fuses current rating | Type 2 (per IEC 60947-4-1): 50A @ 415V, 65 kA available fault current |
---|
UL class K5 and RK5 fuses rating | 90A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
---|
UL class CC and CSA HRCI-MISC fuses rating | 40A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14 |
---|
UL inverse-time circuit breaker | 50A @ 480V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
---|
Rated operational current (Ie) | 9A @ 690V, AC-4 (approximately 200000 ops) |
---|
Rated operational power (Pe) | 7.5kW @ 690V, AC-4 (approximately 200000 ops) |
---|
DIN fuses (gG, gL) current rating | Type 2 (per IEC 60947-4-1): 40A @ 690V, 50 kA available fault current |
---|
UL class J and CSA HRCI-J fuses rating | 40A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14 |
---|
Switching of power transformers | Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30) |
---|
Switching of 3-phase Capacitors | Single capacitor: 9 kVAR @ 240V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH) |
---|
Switching of DC loads | 3-Poles in series:32A @ 110V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
---|
Contacts | 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block |
---|
Function | Reversing contactor |
---|
Rated impulse voltage withstand (Uimp) | 6 kV |
---|
Conventional coil type | True |
---|
Electronic-EI coil type | True |
---|
Rated coil frequency | AC 50/60 Hz, DC |
---|