Part Number |
AF205-30-11-13 |
Long Description |
The AF205-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 110 kW / 400 V AC (AC-3) or 150 hp / 480 V UL and switching power circuits up to 350 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. |
Dimensions |
Product Net Width |
105 mm |
Product Net Depth / Length |
152 mm |
Product Net Height |
196 mm |
Product Net Weight |
2.4 kg |
Technical |
Number of Main Contacts NO |
3 |
Number of Main Contacts NC |
0 |
Number of Auxiliary Contacts NO |
1 |
Number of Auxiliary Contacts NC |
1 |
Rated Operational Voltage |
Main Circuit 1000 V |
Rated Frequency (f) |
Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) |
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A |
Rated Operational Current AC-1 (Ie) |
(1000 V) 40 °C 275 A (1000 V) 55 °C 250 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 55 °C 300 A (690 V) 70 °C 240 A |
Rated Operational Current AC-3 (Ie) |
(415 V) 55 °C 205 A (440 V) 55 °C 205 A (500 V) 55 °C 186 A (690 V) 55 °C 165 A (1000 V) 55 °C 100 A (380 / 400 V) 55 °C 205 A (220 / 230 / 240 V) 55 °C 205 |
Rated Operational Power AC-3 (Pe) |
(415 V) 110 kW (440 V) 132 kW (500 V) 132 kW (690 V) 160 kW (1000 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 55 kW |
Rated Breaking Capacity AC-3 |
8 x Ie AC-3 |
Rated Making Capacity AC-3 |
10 x Ie AC-3 |
Short-Circuit Protective Devices |
gG Type Fuses 400 A |
Rated Short-time Withstand Current Low Voltage (Icw) |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A |
Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A |
Maximum Electrical Switching Frequency |
(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour |
Rated Operational Current DC-1 (Ie) |
(110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A |
Rated Operational Current DC-3 (Ie) |
(110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A |
Rated Operational Current DC-5 (Ie) |
(110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A |
Rated Insulation Voltage (Ui) |
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) |
Main Circuit 8 kV |
Mechanical Durability |
5 million |
Maximum Mechanical Switching Frequency |
300 cycles per hour |
Coil Operating Limits |
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) |
50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V |
Coil Consumption |
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage DC 190 W |
Operate Time |
Between Coil De-energization and NO Contact Opening 37 ... 47 ms Between Coil Energization and NO Contact Closing 25 ... 55 ms |
Connecting Capacity Main Circuit |
Flexible 2 x 50 ... 95 mm² Rigid Al-Cable 1 x 95 ... 185 mm² Rigid Cu-Cable 1 x 6 ... 150 mm² |
Connecting Capacity Auxiliary Circuit |
Flexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 1 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² |
Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type |
Main Circuit: Bars |
Technical UL/CSA |
Maximum Operating Voltage UL/CSA |
Main Circuit 1000 V |
General Use Rating UL/CSA |
(600 V AC) 300 A |
Horsepower Rating UL/CSA |
(200 V AC) Three Phase 60 hp (208 V AC) Three Phase 60 hp (220 ... 240 V AC) Three Phase 75 hp (440 ... 480 V AC) Three Phase 150 hp (550 ... 600 V AC) Three Phase 200 hp |
Environmental |
Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... +70 °C |
Maximum Operating Altitude Permissible |
Without Derating 3000 m |
RoHS Status |
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |