Low Temperature Cooling Liquid Circulator 6L | |||
Introduction | |||
DC series low temperature constant temperature bath is a piece of indispensable laboratory equipment. It is widely used in biological engineering, medicine, food, chemical industry, metallurgy, chemical analysis, oil and other fields, provides a high-precision controllable uniform-temperature constant field source for the user, and is an ideal thermostat for the large, medium and small research institutes, colleges and universities, factory laboratories and quality inspection departments. Please notice: There is a transformer involved in this item, 110V to 220V, so you can connect the power supply with the low temperature cooling liquid circulator through the transformer. | |||
Features | |||
1. The machine adopts microcomputer based temperature control. High accuracy of temperature control. 2. Intelligent digital system can correct the deviation of the temperature measurement, so that the digital resolution is 0.1℃. 3. The refrigeration system has over-heating and over-current multiple protection functions. 4. The machine has intelligent instrument control, so that the machine is easy to operate and has high temperature stability. It also has an alarm function when the temperature reaches the upper and lower limits. 5. Equipped with a fully efficient anti-interference compressor. 6. Cooling rate is higher than those of similar products, lower noise, lower vibration. | |||
Parameters | |||
Model | DC-3006 | ||
Voltage | 110V | ||
Power | 1800W | ||
Volume | 6L | ||
Operating ambient temperature | 5℃-30℃ | ||
Temperature range | -30℃-100℃ | ||
Internal material | 304 stainless steel | ||
Opening Size | 7''*6.2''*5.9(depth) | ||
Size | 17.3''*16.1''*27.9'' | ||
Instruction | |||
1. Remove the package, clean the working platform. 2. Add liquid medium into tank, enable the medium level to be 30mm(1.18'') lower than the working platform 3. Connect circulating pump inlet and outlet pipes ①When the pump doesn't need to carry out outer circulation, just need to connect the inlet pipe with the outlet pipe through a hose ②When the pump is used for the outer circulation of the constant temperature liquid, please connect the outlet pipe of the pump with the inlet pipe of the container outside of the tank through the 1# pipe, and connect the inlet pipe of the pump with the outlet pipe of the container outside of the tank through another pipe.
| |||
Precautions | |||
1. Before using the tank, it is necessary to add liquid medium, otherwise, it will damage the heater. The medium level must be lower than the platform. 2. The selection of the liquid medium in the tank shall be in accordance with the following principles: A. When the operating temperature is 5℃-85℃, the liquid medium is usually water B. When the operating temperature is 85℃-95℃, the liquid medium can be 15% glycerin-water solution C. When the operating temperature is lower than 5℃, the liquid medium is generally alcohol or freezing liquid 3. In order to prolong the service life of the refrigeration system, the system adopts startup protection. Once the refrigeration system stops working, it will need 10-20minutes' space to turn on the switch again (for example, when the switch is turned on to start the compressor in less than 10 minutes from the last operation, it is a normal phenomenon that the system will not start.) 4. Power supply should be greater than the total power of the machine, the power supply must have a good grounding device. 5. The machine should be placed in a dry and ventilated place. 6. When the working temperature is very low, please do not put your hands into the tank to avoid frostbite. 7. Cut off power supply when operation is finished. . | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
![]() | |||
Detail Display | |||
No.1 Large LCD display, convenient and quick input key, shift key and increase key, decrease key and so on. | ![]() | ||
No.2 Large opening size, enlarging operating space. | |||
No.3 The angular design is more beautiful and more stable. | ![]() | ||
![]() | No.4 Drainage valves make drainage more convenient. | ||
No.5 There is a transformer involved in this item, 110V to 220V, so you can connect the power supply with the low temperature cooling liquid circulator through the transformer. | ![]() | ||
We also have other models to choose from, please contact us if you need it. | |||
![]() | |||
Item included | |||
Low Temperature Cooling Liquid Circulator 6L (020270) |
Shipping & Handling Details |
Default Shipping Cost or Free Shipping Information: Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays. Sales tax / Customs duties: Any sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer. Sales Tax of 8% will be applied for orders shipped within the state of California. Damage In Shipping: Email or call us First! We will work with you to get the case resolved in the fastest method. |
Return / Refund |
If you are not 100% happy with your purchase, please contact Us. Please don't directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding. Returns & Exchanges All returns must be made within 14 days of delivery date. Items must be in new, unused condition, with all original materials included with the shipment. A partial refund may be applied for opened or damaged items, depending on the condition. Returns that are the result of our seller's error: Buyer will receive a full refund of the item as well as shipping charges Defective & Damaged Products |
Payment |
eCheck Issues: Payments via eCheck do not clear immediately. Usually you will wait 5-7 days after checkout for it to clear. Then we will arrange shipments for you. |
Warranty & Feedback |
6 months' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost. Any warranty shipping cost to us is responsible by buyer. Any shipping cost to buyer is responsible by the seller. |