2400W 24V Solar Inverter Hybrid 110V/120V Off Grid 80A Charge Controller PV 80V

This is a multi-function inverter/charger that integrates the functions of an inverter, solar charger, and battery charger to provide uninterrupted power support while maintaining a compact and portable design. Its comprehensive LCD display offers user-configurable settings and easy-to-use buttons for adjusting battery charging current, AC/solar charging priority, and selecting acceptable input voltage based on different applications.

Features
1. Pure sine wave inverter
2. Configurable input voltage range for home appliances and personal computers via LCD setting
3. Configurable battery charging current based on applications via LCD setting
4. Configurable AC/Solar Charger priority via LCD setting
5. Compatible to mains voltage or generator power
6. Auto restart while AC is recovering
7. Overload/ Over temperature/ short circuit protection
8. Smart battery charger design for optimized battery performance
9. Cold start function
Specification
Table 1 Line Mode Specifications
INVERTER MODEL | POW-LVM2.4K-24V | ||
Input Voltage Waveform | Sinusoidal (utility or generator) | ||
Nominal lnput Voltage | 120Vac | ||
Low Loss Voltage | 95Vac±7V(UPS);65Vac±7V(Appliances) | ||
Low Loss Return Voltage | 100Vac±7V(UPS);70Vac±7V(Appliances) | ||
High Loss Voltage | 140Vac±7V | ||
High Loss Returm Voltage | 135Vac±7V | ||
Max AC Input Voltage | 150Vac | ||
Nominal Input Frequency | 50Hz/60Hz(Auto detection) | ||
Low Loss Frequency | 40±1Hz | ||
Low Loss Return Frequency | 42±1Hz | ||
High Loss Frequency | 65±1Hz | ||
High Loss Return Frequency | 63±1Hz | ||
Output Short Circuit Protection | Circuit Breaker | ||
Efficiency(Line Mode) | >95%(Rated Rload,battery full charged) | ||
Transfer Time | 10ms typical(UPS);20ms typical(Appliances) | ||
Output power derating: When AC input voltage drops to 95V,the output power willbe derated. |
![]() |
Table 2 Inverter Mode Specifications
INVERTER MODEL | POW-LVM2.4K-24V |
Rated Output Power | 3KVA/2.4KW |
Output Voltage Waveform | Pure Sine Wave |
Output Voltage Regulation | 120Vac±5% |
Output Frequency | 60Hz |
Peak Efficiency | 90% |
Overload Protection | 5s@≥150%load;10s@110%~150%load |
Surge Capacity | 2*rated power for 5 seconds |
Nominal DC Input Voltage | 24Vdc |
Cold Start Voltage | 23.0Vdc |
Low DC Warning Voltage | |
@load<20% | 22.0 Vdc |
@20%≤load<50% | 21.4Vdc |
@load≥50% | 20.2 Vdc |
Low DC Warning Return Voltage | |
@load<20% | 23.0 Vdc |
@20%≤load<50% | 22.4Vdc |
@load≥50% | 21.2 Vdc |
Low DC Cut-off Voltage | |
@load<20% | 21.0Vdc |
@20%≤load<50% | 20.4 Vdc |
@load≥50% | 19.2 Vdc |
High DC Recovery Voltage | 29Vdc |
High DC Cut-off Voltage | 31Vdc |
No Load Power Consumption | <20W |
Saving Mode Power Consumption | <10W |
Table 3 Charge Mode Specifications
INVERTER MODEL | POW-LVM2.4K-24V | |
Charging Algorithm | 3-Step | |
Utility Charging Mode | ||
AC Charging Current | 20/30Amp(@Vvp=120Vac) | |
Bulk Charging Voltage |
Flooded Battery AGM/Gel Battery |
29.2 |
AGM / Gel Battery | 28.2 | |
Floating Charging Voltage | 27Vdc | |
Charging Curve | ||
Solar Charging Mode | ||
Max.PVArray Power | 1200W | |
Charging Current(PWM) | 50Amp | |
System
|