Product information | |
Nominal Voltage | 12,8V |
Rated Capacity | 300Ah |
Charging Voltage | 14,2 - 14,6V |
Energy | 3,840Wh |
Max. Charging Current | 200A |
Recommended Charging Current | 50A~100A |
Max.Discharging Current | 200A(400A Peak in 3~5s) |
Low Cut-off Voltage | 10V |
Deep Cycle | ≥15000 times |
Dimensions(mm) | L385 * B190 * H245 mm(15.2 x 7.5 x 9.7 inches ) |
Item Weight(kg) | about 25kg |
Number of cells | 4pcs Grade A LiFePO4 Cells |
Battery Terminals | M8 |
Operating Temperature | Charging:0℃ to 45℃; Discharging:-20℃ to 60℃; Storage: -10℃ to 50℃ |
Storage Condition | Store at ≥50% Capacity, Recharge Every 3 Months |
1.Certificate: CE ROHS MSDS UN38.3
2.Upgrade Parts/Accessories: Grade A
3.Material: Lithium iron phosphate
4.Max continuous charge current: 200A
6.Max continuous discharge current: 200A
7.Peak discharge current: 400A in three to five seconds
8.Voltage: 12V
9.Maximum protection voltage: 14.6V
10.End Voltage: 10V
12.Terminal: M8
14.Charging temperature: 0℃-45℃
16.Discharge temperature: -20℃-60℃
17.Storage temperature: -10℃-50℃
MOSEWORTH LiFePO4 12V 300Ah battery
Product brochure
Warm Tips for Connections
1. To connect in series or /and parallel, batteries should meet the below charging/ discharging voltage). As there are subtle differences in the conditions:
a). identical batteries with the same battery capacity (Ah) and BMS (A);
b). from the same brand (as lithium battery from different brands has their
special BMS)
c. purchased in near time (within one month).
2.Restriction for parallel and series connection:
Up to 5 identical batteries for serial connection up to 60 V and no limit for parallel connections.
3.Two necessary steps before connecting:These two steps are necessary to reduce the voltage difference between batteries, and through these, the battery system can provide the best of it in series and/or parallel.
Step 1: Fully Charge the batteries separately.
Step 2: Connect the batteries one by one in parallel and leave them together for 12-24h. And then you can connect your batteries in series and/or parallel.
4.Or if you need to load and unload them together, the following steps should be taken:
A: Fully recharge the batteries separately before the first connections.
B: Disconnect the connections among the batteries and recharge the batteries separately once a month.
C:If there is slight voltage difference among batteries during series use, please read page 38 of the manual.